Heat Fab 9393 Saf-T Vent EZ Seal - 3" Horizontal Wall Thimble Round Face
Availabilty
Usually Ships in 1 Business Day
To use this thimble, the vent must be uninsulated for a minimum distance prior to passing through a combustible wall. A minimum distance of 18 inches is required for appliance flue gas temperatures up to 400° F. A minimum distance of 6 feet is required for appliance flue gas temperatures of 400 - 480° F. The opening must be 6-1/2 inches in diameter for either 3 or 4 inch diameter Saf-T Vent systems. The wall thimble is designed to adapt to any wall thickness from 3.5" to 6" thick. If the wall is thicker than 6", the thimble may be extended using a piece of 6" diameter snaplock or welded-seam galvanized pipe. The vent system may be terminated using any terminal Listed for use with the appliance. The wall thimble may be painted to match the decor.
- Horizontal Wall Thimble
- Round Face
- 3" Diameter
- AL29-4C Stainless Steel
- Saf-T Vent Systems
| EZ Seal Catalog & Dimensional Data |
![]() | EZ Seal Brochure |
![]() | Heatfab Weight Per Foot |
![]() |
View Adapter Chart |
| EZ Seal Install (3" to 5") |
![]() |
EZ Seal Install (6" to 16") |