Eccotemp Descaler Cleaning Kit with Pump, Hose, Bucket and 1 Quart of Solution

The Eccotemp System Descaler Kit has been designed to work with Tankless Water Heaters that provide 3/4" hot and cold service connections. Eccotemp Flow-Aide System Descaler is NSF approved and safe to dispose of in drains. RECOMMENDED USES: Ice Machines Humidifiers Water Heaters Boilers Heat Exchangers Chillers Vacuum Pumps Condensers Evaporators Tanks Potable Waterlines Water Operated Equipment The pump is 500 GPH.

FLOW-AIDE System Descaler quickly dissolves water scale, lime, rust, and other water formed deposits, restoring efficiency to most all appliances. FLOW-AIDE System Descaler is a non-toxic concentrate which is certified to NSF/ANSI 60 for use as a cleaner in potable water systems. FLOW-AIDE System Descaler is specifically designed to dissolve the toughest water scale, lime, and rust deposits from virtually any piece of water based equipment. This powerful, yet totally safe, liquid is non-toxic, non-flammable, non-hazardous, non-corrosive and biodegradable. FLOW-AIDE System Descaler will not harm your personnel, equipment or our environment!

IMPROVE EQUIPMENT EFFICIENCY: Water scale deposits are a significant cause of heat transfer loss, along with the subsequent increase in energy costs. In fact, even a thin layer of scale (1/32") can cause a 30% increase in the cost to operate that piece of equipment. Keeping the heating passages free of mineral deposits significantly improves efficiency, conserves energy, extends the useful life of the equipment, and saves you time & money.

Kit Includes:

1 - 3.5 Gallon Bucket
1 - 500 GPH Pump
2 - 5 Foot Rubber Hoses
1 - Quart Flow-Aide

 *The solution is biodegradable with a BOD value of 16 mg/l. This normally allows the solution to be water flushed down sewers. Check with local ordinances and regulations in your area prior to disposal.

Descaling Procedure:

1. Disconnect power to water heater.

2. Close hot and cold isolation and service valves and remove service caps.

3. Pour 1.25 gallons of water into bucket and place under water heater. 

4. Add contents of 1 quart bottle of Whitlam Flow-Aide into bucket (Bucket should be filled approximately 1/2 full). 

The higher the concentration the faster the system will be cleaned.  Minimum dilutions is 1 part water to 1 part Flow-Aide.  Be sure to have enough solution to keep the pump  submersed when in use.

5. Connect one hose to pump, and other end of same hose to cold service valve. Place pump in bucket.

6. Connect second hose to hot service valve. Place other end in bucket.

7. Open both hot and cold service valves.

8. Plug pump into grounded receptacle.

9. Allow pump to circulate Whitlam Flow-Aide solution through heater for 30-45 minutes. Unplug pump.

10. Close cold service valve. Remove hose from cold service valve, and replace service cap.

11. Disconnect the hose from the pump and remove pump from bucket. Discard Whitlam Flow-Aide solution.

12. Flush tankless water heater for 3-5 minutes or until water flows clear by opening the cold isolation valve and allowing water to exit through the hot service valve into a drain or bucket. If using a bucket, empty periodically.

13. Close hot service valve. Remove hose from service valve and replace service cap.

14. Open hot isolation valve.

15. Connect power to water heater and return appliance to service.